APC Smart-UPS On-Line, 5kVA 5000va, Rack/Tower, 230V, 2x IEC C13+1x IEC C19+Hard wire 3-wire (H+N+E) outlets, Network Card SRTG5KXLI

  • 8,962,000.00 TZS
    Unit price per 
Tax included. Shipping calculated at checkout.

Only 2 left!

Key Features

  • Output power capacity: 6.0kWatts / 6.0kVA
  • Output Connections: (1) IEC 60320 C19 (Battery Backup), (2) IEC 60320 C13 (Battery Backup), (1) Hard wire 3-wire (H N + E) (Battery Backup)
  • Nominal Output Voltage: 230V
  • Nominal Input Voltage: 230V
  • Input Connections: Hard wire 3-wire (1P + N + E)
High density, double-conversion on-line power protection with scalable runtime
Includes: Smart UPS signalling RS-232 cable, User manual

  • Automatic restart of loads after UPS shutdown
    Automatically starts up the connected equipment upon the return of utility power.
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • ECO Mode
    Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
  • LCD Status Display
    Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

Smart-UPS On-Line Features & Benefits

Protection

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Cold-start capable
Provides temporary battery power when the utility power is out.

Marketing features

Save time with easy and convenient remote/network accessibility.
Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Avoids costly power problems by keeping your IT equipment and data protected and available .
Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Peace of mind that comes with full equipment compatibility and reliability of a leader
Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Low operating and maintenance costs with proven reliability and intelligent battery management .
Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.


Manageability

Serial connectivity
Provides management of the UPS via a serial port.
Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
LED status indicators
Quickly understand unit and power status with visual indicators.
Intelligent Card Slot
Customize UPS capabilities with management cards.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.


Serviceability

Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Audible alarms
Provides notification of changing utility power and UPS power conditions
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)


Availability

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Scalable runtime
Allows additional run time to be quickly added as needed.


Adaptability

Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.

TECH SPECS

Overview

  • Main Input Voltage: 230 V
  • Main Output Voltage: 230 V
  • Rated power in W: 5000 W
  • Rated power in VA: 5000 VA
  • Nb of power socket outlets: 2 IEC 60320 C13, 1 IEC 60320 C19
  • Output connector type: Hard wire 3-wire (H N + E) 1
  • Battery type: Lead-acid battery
  • Provided equipment: Smart UPS signaling RS-232 cable, User manual, USB cable


Physical

  • Height: 17.78 cm
  • Width: 44 cm
  • Depth: 62 cm
  • Net weight: 51.9 kg
  • Mounting mode: Rack-mounted with kit ( NOT INCLUDED)
  • USB compatible: No
  • Package weight: 59 kg

Input

  • Network frequency: 40...70 Hz auto-sensing
  • Number of input connectors: 1 hard wire 3-wire (1P + N + E)
  • Input voltage limits: 160...285 V
  • Maximum input current: 30 A
  • Switching current capacity: 40 A

Output

  • Maximum configurable power in W: 5000 W
  • Harmonic distortion: Less than 2 %
  • Output frequency: 50/60 Hz +/- 3 Hz sync to mains
  • Crest factor: 3 : 1
  • UPS type: Double conversion online
  • Wave type: Sine wave
  • Bypass type: Internal bypass (automatic and manual)
  • Full load runtime: 00:03:30 5000 W
  • Half load runtime: 00:10:20 2500 W
  • Maximum configurable power in VA: 5000 VA


Environmental

  • Ambient air temperature for operation: 0…40 °C
  • Relative humidity: 0…95 % non-condensing
  • Operating altitude: 0...6600 ft
  • Ambient air temperature for storage: -15…45 °C
  • Storage Relative Humidity: Non-condensing 0…95 %
  • Storage altitude: 0.00…15240.00 m
  • Acoustic level: 55 dBA
  • Heat dissipation: 1108.95 Btu/h
  • IP degree of protection: IP20

Batteries & Runtime

  • Run Time: View Runtime Graph
  • Number of battery filled slots: 2
  • Number of battery free slots: 0
  • Battery recharge time: 4 h
  • Additional information: Configurable for 220 : 230 or 240 nominal output voltage
  • Battery voltage: +/- 96 V
  • Battery charger power: 239 W rated
  • Battery power in VAH: 960 VAh capacity, 960 VAh runtime
  • Battery option: SRTG192XLBP4 1 2651 VAh, SRTG192XLBP4 2 4424 VAh, SRTG192XLBP4 3 6314 VAh, SRTG192XLBP4 4 8118 VAh
  • Extended runtime: 1

Communications & Management

  • Preinstalled device: Network management card
  • Control panel: LED Status display with on line on battery, Multifunction LCD status and control console
  • Alarm: Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
  • Emergency power off: Yes